Fire protection F 60-B (REI 60) AGEPAN® UDP N+F
Construction type for installing a structural enclosing wooden post-and-beam construction of fire resistance class F 60-B (REI 60) acccording to DIN 4102-2:*1977-09 consisting of a solid construction timber (KVH) stud frame with required cavity insulation as well as inner and outer lining for one-sided fire exposure from the external wall side.
Specifications
Construction Example | Product | Nominal Thickness (mm) |
---|---|---|
Inside | Gypsum board | ≥ 12,5 |
AGEPAN® THD Install | ≥ 40 | |
AGEPAN® OSB 3 ECOBOARD | ≥ 15 | |
Solid construction timber | ≥ 60 x 140 | |
Mineral wool (Klemmrock) | ≥ 140 | |
Outside | AGEPAN® UDP T+G | ≥ 22 |
Inside | |
---|---|
Product | Gypsum board |
Thickness | ≥ 12,5 |
Product | AGEPAN® THD Install |
Thickness | ≥ 40 |
Product | AGEPAN® OSB 3 ECOBOARD |
Thickness | ≥ 15 |
Product | Solid construction timber |
Thickness | ≥ 60 x 140 |
Product | Mineral wool (Klemmrock) |
Thickness | ≥ 140 |
Product | AGEPAN® UDP T+G |
Thickness | ≥ 22 |
Outside |
Construction example. Details, exact dimensions and thicknesses can be found in the respective test certificates, standards and building regulations. Please observe the processing instructions.
System’s components
AGEPAN® UDP T+G
The stable sarking board. Thermal-insulating and soundabsorbing in roof and wall.
KNOW MORE
AGEPAN® THD INSTALL
Installation level or pressure-resistant interior insulation in roof and wall areas.
KNOW MORE
AGEPAN® OSB 3 ECOBOARD®
The load-bearing panel. For universal use in timber frame constructions.
KNOW MORE
Where to buy
Wide network of specialized distributors, available to receive your orders